- Serial Number -
ipmitool fru print 0
- power supply -
ipmitool sdr type 'power supply'
- Processor -
ipmitool sdr type Processor
- temperature -
ipmitool sdr type temperature
- sel list -
ipmitool sel list
- lan -
ipmitool lan print 3
- ipmi 명령어 확인 -
ipmitool cmd help
- Disk -
avsysreport pdisk
avsysreport pdisk |egrep 'Status|Physical Disk ID'
-----------------------------------------------------------------------------------------
ipmitool
No command provided!Commands:
raw Send a RAW IPMI request and print response
i2c Send an I2C Master Write-Read command and print response
spd Print SPD info from remote I2C device
lan Configure LAN Channels
chassis Get chassis status and set power state
power Shortcut to chassis power commands
event Send pre-defined events to MC
mc Management Controller status and global enables
sdr Print Sensor Data Repository entries and readings
sensor Print detailed sensor information
fru Print built-in FRU and scan SDR for FRU locators
gendev Read/Write Device associated with Generic Device locators sdr
sel Print System Event Log (SEL)
pef Configure Platform Event Filtering (PEF)
sol Configure and connect IPMIv2.0 Serial-over-LAN
tsol Configure and connect with Tyan IPMIv1.5 Serial-over-LAN
isol Configure IPMIv1.5 Serial-over-LAN
user Configure Management Controller users
channel Configure Management Controller channels
session Print session information
sunoem OEM Commands for Sun servers
kontronoem OEM Commands for Kontron devices
picmg Run a PICMG/ATCA extended cmd
fwum Update IPMC using Kontron OEM Firmware Update Manager
firewall Configure Firmware Firewall
delloem OEM Commands for Dell systems
shell Launch interactive IPMI shell
exec Run list of commands from file
set Set runtime variable for shell and exec
hpm Update HPM components using PICMG HPM.1 file
ekanalyzer run FRU-Ekeying analyzer using FRU files
-----------------------------------------------------------------------------------------
root@idcavamar:~/#: ipmitool sdr type
Sensor Types:
Temperature Voltage
Current Fan
Physical Security Platform Security
Processor Power Supply
Power Unit Cooling Device
Other Memory
Drive Slot / Bay POST Memory Resize
System Firmwares Event Logging Disabled
Watchdog System Event
Critical Interrupt Button
Module / Board Microcontroller
Add-in Card Chassis
Chip Set Other FRU
Cable / Interconnect Terminator
System Boot Initiated Boot Error
OS Boot OS Critical Stop
Slot / Connector System ACPI Power State
Watchdog Platform Alert
Entity Presence Monitor ASIC
LAN Management Subsystem Health
Battery Session Audit
Version Change FRU State
ipmitool sdr type Current
ipmitool sdr type Memory
ipmitool sdr type 'System Event'
ipmitool sdr type 'Version Change'
------------------
Check electric fan problem
ipmitool sdr type fan
Check virtual disk problem
avsysreport vdisk
Check disk controller problem
avsysreport controller
Check system log
ipmitool sel info
Totally check hardware problem
avsysreport chassis
Check power supply problem
avsysreport powersupplies
Temperature check
avsysreport temperatureprobe
Memory check
avsysreport memorymodules
Hardware log collection
sysinfo -ni
'Backup Solution & IT Study > Server' 카테고리의 다른 글
[DellEMC PowerEdge] Linux OM(OpenManage) 설치 (0) | 2021.03.12 |
---|---|
[Server DellEMC]DellEMC OM 서버 점검 명령어 & Log Clear 명령어 (0) | 2021.03.02 |
[Server DellEMC]DellEMC Server iDrac CLI 설정 방법 (416) | 2021.03.02 |
댓글